fluorescence microscopy
Getting the most from fluorescent proteins
Fluorescent proteins (FPs) are an indispensable component of the biology toolbox, providing a robust and straightforward method to optically label nearly any protein of interest.
While most FPs can be used for a wide variety of experimental setups and conditions, getting the best quality data from your hard efforts requires some forethought. Here are a few tips to get the most out of FP imaging:
1.Reduce pre-measurement photobleaching.
All FPs photobleach upon exposure to excitation light. Some, like commonly used YFPs, bleach rather quickly, while others, such as Allele’s mTFP1, are substantially more photostable. However, even the most photostable FPs can be susceptible to excessive pre-measurement bleaching if precautions are not taken.
While searching for your favorite cell on the microscope, try to use the lowest possible excitation light intensity. Close the shutter when you’re setting up software or other experimental apparatus, and use short exposure times whenever possible during focusing.
2.Consider pH and other variables.
Most FPs are somewhat sensitive to acidic pH. Some, such as mTFP1 and many of the red FPs, are reasonably resistant to pH changes, while others, such as EYFP, are highly sensitive. If you’re imaging acidic compartments such as lysosomes or plant vacuoles, you’re unlikely to see any fluorescent signal if you’re using EYFP or any other pH-sensitive FP, so choose wisely!
Information on the fluorescence pKa (the pH at which 50% of the fluorescence emission is quenched) of new fluorescent proteins is generally easy to find, so do your homework!
3.Be careful with fusions and linkers.
One big advantage of using FPs is that they may be genetically fused to virtually any protein of interest. While FPs usually have a negligible effect on the properties of their fusion partners, it’s always a good idea to double-check and validate data on new proteins.
If you don’t know where your protein should localize, check both N- and C-terminal FP fusions to be sure they give the same results. If not, validate your localization by other methods, such as antibody staining. If you can devise a functional assay for your FP-labeled protein, this is also a good way to be sure the fusion isn’t causing trouble.
If you’re having problems with a particular FP fusion, try a few different linkers between the FP and the protein of interest. Floppy linkers, such as poly-(Gly-Gly-Ser-Gly-Gly-Thr) frequently work well, but occasionally rigid linkers (such as poly-proline) or other sequences will give better results. Unfortunately, the process of optimizing a fusion construct is largely empirical.If you can put in the effort early in your experiments to produce the best possible FP fusion, you’ll benefit greatly in later experiments!
Categories
- Allele Mail Bag
- cGMP
- Customer Feedback
- Fluorescent proteins
- iPSCs and other stem cells
- nAb: Camelid Antibodies, Nanobodies, VHH
- Next Generation Sequencing (NextGen Seq)
- NIH Budget and You
- oligos and cloning
- Open Forum
- RNAi patent landscape
- SBIR and Business issues
- State of Research
- Synthetic biology
- Uncategorized
- Viruses and cells
- You have the power
Archives
- October 2018
- April 2018
- March 2018
- January 2018
- October 2017
- September 2017
- August 2017
- March 2017
- February 2017
- January 2017
- November 2016
- September 2016
- August 2016
- July 2016
- June 2016
- May 2016
- April 2016
- February 2016
- October 2015
- September 2015
- August 2015
- June 2015
- March 2015
- January 2015
- December 2014
- March 2014
- February 2014
- January 2014
- December 2013
- November 2013
- October 2013
- September 2013
- August 2013
- July 2013
- June 2013
- May 2013
- April 2013
- March 2013
- January 2013
- December 2012
- November 2012
- October 2012
- September 2012
- August 2012
- July 2012
- May 2012
- April 2012
- February 2012
- January 2012
- December 2011
- November 2011
- October 2011
- September 2011
- August 2011
- July 2011
- June 2011
- May 2011
- April 2011
- March 2011
- February 2011
- January 2011
- December 2010
- November 2010
- October 2010
- September 2010
- August 2010
- July 2010
- June 2010
- May 2010
- April 2010
- March 2010
- February 2010
- January 2010
- December 2009
- November 2009
- October 2009
- September 2009
- August 2009
- July 2009
- June 2009
- May 2009
- April 2009
- March 2009
- February 2009
- January 2009
- December 2008
- October 2008
- August 2008
- July 2008